The first life-saving ECG device
The AT-101 easy is the world’s only ambulatory ECG device with an integrated defibrillator, providing full control of the situation. The AT-101 easy combines the AT-101 with the revolutionary FRED® easyport®, offering the innovative options and monitoring features of both devices. The user is guided through the life-saving measures by comprehensible displayed and voice messages.
Features:
Intuitive and easy to use with direct keys for the most important functions
Simultaneous 12-lead Resting ECG recording with standard ECG measurements
Integrated, graphical 3-channel LCD
Easy Print: Integrated high-resolution 3-channel thermal printer
Various user-programmable report formats on internal printer
Storage and serial data transfer for Resting ECG data to a PC (with memory option)
Voice Prompt
Extremely gentle defibrillation energy using Multipulse Biowave® (biphasic pulsed defibrillation impulse, patented) A quantum leap in emergency medical care.
A new defibrillation technology opens new perspectives for improved chances of survival after out-of-hospital cardiac arrest.
For the first time, SCHILLER developed a defibrillation waveform, that takes account of the excitation process and actual physiological behaviour of cardiac cells, and protects them.
The new technology called Multipulse Biowave®
makes it possible to reduce the quantity of energy required for defibrillation to a point, where the risk of injuring heart tissue is virtually eliminated. These revolutionary benefits are derived from the unique characteristics of a new type of waveform, a pulsed biphasic waveform:
Optimised Form and Duration
The waveform (two phases of 4 ms each) is chopped (pulsed) at a high frequency, which leads to a very reduced energy applied to the patient, together with an improved effectiveness.
Two Capacitors
Multipulse Biowave® is using two capacitors, which allows the second (negative) phase of the pulse to be sized freely to meet the physiological requirements, in order to effectively block all re-entry loops causing fibrillation.
Effectiveness Reserve
With a defibrillation threshold of about 60 J. (i.e. less than 1/3 of the energy amount of a usual monophasic pulse of 200 J.) and a maximal applied energy of 180 J. Multipulse Biowave has a reserve of effectiveness (reserve of effective energy be-fore it can be considered potentially harmful) ratio of 3. Thanks to these very low energies associated with such an effectiveness reserve, Multipulse Biowave® has the best chances to improve the rates of survival in case of cardiocirculatory arrest.
Less is more
Less Energy! More Effectiveness!
The new defibrillation technology Multipulse Biowave® is now released worldwide in the FRED range of semi-automatic defibrillators from SCHILLER.

Ref: 0.083000

£2,871.00 (£3,301.65 Including VAT)

For Online Help Click the Live Chat button

Payment
We accept all major credit cards, cheques and money transfers.

DELIVERY, TITLES & RISK
Any time or date stated for delivery is an estimate only. OMS makes every effort to despatch goods on time, but does not accept liability for failure to deliver within the stated time. If OMS is unable to deliver the goods within 30 days of the date of the order, the Customer will be entitled to cancel the order and require any monies paid to OMS in respect of that order to be refunded.